Improving the indoor air quality of newly-built schools with the bake-out method

Won-Mo Gal1, Hee-Seon Ryu2, Young-Ah Rha3, Woo-Taeg Kwon1*
1Department of Environmental Health and Safety, Eulji University
2Department of Urban Planning, Gachon University
3Department of Food Technology and Services, Eulji University
*Corresponding author Tel : +82-31-740-7145
E-mail : awtkw@eulji.ac.kr
22 November, 2014 17 December, 2014 24 December, 2014

Abstract

We studied the changes in the concentration of total volatile organic compounds generated in newly-built schools (five kindergarten schools, two primary schools, three middle schools, one high school) by the bake-out. Samples were collected in classrooms. By using the bake-out technique the removal efficiency of total volatile organic compounds was 89.1%(maximum) and 27.5%(minimum). By using this bake-out technique the removal efficiency was 42.5% greater than the ventilation method. Therefore, we determined that it is appropriate to apply both the bake-out and ventilation methods in the case of newly-built schools.