Journal Abbreviation : ‘J. Odor Indoor Environ.’ Frequency : Quarterly Doi Prefix : 10.15250/joie. ISSN : 2288-9167 (Print) / 2288-923X (Online) Year of Launching : 2014 Publisher : Korean Society of Odor Research and Engineering & Korean Society for Indoor Environment Indexed/Tracked/Covered By :
1Department of Environmental Health and Safety, Eulji University 2Department of Health Care Management, Catholic Kwandong University 3Sunil Environment Co. Ltd
The purpose of this study is to confirm the removal effect of odorous gas through the multi process. Thecombination of Scrubber, UV and Adsorption was analyzed using the odor gas of reservoir. Analysis was carriedout for six times in total and collection was made once per each process. Sampling was performed in the afternoonduring August (1:00pm~4:00pm). Multi process has been designed to facilitates the accessories exchange. Theadvantage is that it facilitates the replacement of the activated carbon and it is convenient to change the type ofchemical according to the type of pollution materials. As a result, for odor gas removal efficiency, ammonia 91.8%,trimethylamine 72.0%, hydrogen sulfide 99.9%, methyl mercaptan 99.9% were removed respectively. Removalefficiency of the process is the scrubber (alkali), activated carbon adsorption, scrubber (acid) and UV procedurefrom the highest order. Further studies on the operating method and efficiency of multi process by the change ofwind speed and chemical are recommended.