ISSN : 1738-4125(Print)
ISSN : 2287-7509(Online)
Journal of Odor and Indoor Environment Vol.3 No.1 pp.45-53
DOI :
충남지역 일부 다중이용시설에서 Bioaerosol의 농도에 관한 연구
이치원, 이종대, 전용택, 손부순*
순천향대학교 환경보건학과
A Study on Bioaerosol Concentration in Public Facilities, Chung-Nam Province Area
Bu Soon Son*
, Che Won Lee, Jong Dae Lee, Yong Teak Jeon
Department of Environmental Health Science SoonChunHyang University
Abstract
We surveyed the concentrations of PM10, O3, and bioaerosol in public facilities including restaurants,offices, and private academies in Chung-Nam province area. During 3 months (from August 30, 2005), thebioaerosol concentrations were measured by a single stage air cascade sampler using the inertia collisioncatching method for the flux of 28.29 ℓ/min. The mean values were measured as 101.1㎍/㎥ for PM10 and12.4 ppb for O3.The concentrations of colony for bacteria and fungi were 464 and 287 CFU/㎥ in restaurants, 223 and 271CFU/㎥ in offices, and 259 and 107 CFU/㎥ in private academics.It is thus suggested that the regulation of indoor air conditions should be amended to control the quantityof bioaerosol in public facilities.
Reference