경북도내 일부학교 교실의 실내공기질 평가

안상영*, 김모근, 김옥순, 이용직, 나채근, 이춘우, 박재형
경상북도보건환경연구원

A Survey on the Indoor Air Quality of Some School Classroom in Gyeongbuk area

Sang-Young An*, Mo-Geun Kim, Ouk-Soon Kim, Chae-Geun Na
Gyeongsanbuk-Do Institute of Health and Environment

Abstract

This study was performed to investigate the characteristics of indoor air quality (IAQ) in elementary andmiddle schools in Gyeongbuk area from July to November 2006 . The measurements of indoor air pollutantswere made to cover such components as PM-10, CO2, CO, NO2, O3, HCHO, TVOC, TBC, and Radon fromschool classrooms. The results of this study can be summarized as follows: all of them were less than IAQstandards of Korea. The mean concentration were measured by 43.0 ㎍/㎥ (PM-10), 745 ppm (CO2), 56.1 ㎍/㎥(HCHO), 350 CFU/㎥ (TBC), 0.026 ppm (O3), 0.6 ppm (CO), and 59.2 ㎍/㎥ (TVOC). Radon was not detectedin all surveyed classrooms. The I/O ratio of PM-10 was 0.8∼1.4, while that for HCHO was 5.7∼9.0.Therefore, it was concluded that the indoor pollution of formaldehyde was very serious in classroom.