신축 공동주택에서 밀폐시간 증가에 따른 실내공기 오염물질의 농도변화

장성기*, 임수길, 이태형, 천재영, 류정민, 서수연
국립환경과학원 실내환경과

The Variation in Concentration of Indoor Air Pollutants in relation with charges in Airtight Time at New Apartment

Seong-Ki Jang*, Soo-Gil Lim, Tae-Hyung Lee, Jae-young Chun, Jung-Min Ryu, Soo-Yun Seo
Indoor Air Quality Division, National Institute of Environmental Research

Abstract

This study was carried out to evaluate the characteristics of volatile organic compounds (VOCs) andaldehydes emission as a function of airtight time in new apartment. Sampling was undertaken at 34 newapartments located in 4 different cities of Korea from February to November 2005. The measurement datawere collected every one hour from 10 a.m. to 6 p.m. toward increasing airtight time in a day. Theconcentrations of VOCs and aldehydes were analysed by GC/MS and HPLC method, respectively. Thesemethods showed good sensitivity, linearity, and repeatability. In this study, the most abundant compounds atnew apartments appeared to be toluene, m,p-xylene, formaldehyde and acetone. Moreover, the concentrationvariations at a closed rooms progressively increased by airtight time of 5 hours. Airtight time of newapartment was a most important and affective factor which influenced concentration change.