Journal Search Engine
Download PDF Export Citation Korean Bibliography PMC Previewer
ISSN : 1738-4125(Print)
ISSN : 2287-7509(Online)
Journal of Odor and Indoor Environment Vol.3 No.4 pp.417-427
DOI :

실내 공기청정기의 오존 발생량 및 음이온 발생의 상관 특성

한방우, 김용진*, 김학준, 김영복, 장성기1), 이우석1)
한국기계연구원 청정환경기계연구센터, 1)국립환경과학원 실내환경과

Characteristics of Ozone Emission and Negative Ion Generation for Indoor Air Cleaners

Yong-Jin Kim*, Bangwoo Han, Hak-Joon Kim, Yong-Bok Kim, Seong-Ki Jang1), Woo-Seok Lee1)
Environmental System Research Center, Korea Institute of Machinery & Materials(KIMM)
1)Indoor Air Quality Division, National Institute of Environmental Research(NIER)

Abstract

Ozone has become a significant pollutant not only outdoors but also indoors. The ozone emission test wasconducted for the sum of forty five air cleaners selected in the online shops and department stores.Negative ion emission test was also conducted for the selected fifteen ones which had the function togenerate negative ions. Filter-type and complex type air cleaners emitted ozone less than 0.05 ppm, thestandard of indoor ozone emission of air cleaner. Wet type ones emitted no ozone. In the case of ionizertype, 66.7% in the nine ones emitted ozone about 1.4~10 times larger than 0.05ppm. Most of air cleanersused a pin corona discharge emitted large amount of ozone. Those which used carbon fiber emitted littleozone in spite of generating a lot of negative ions.