Journal of Odor and Indoor Environment Vol.5 No.4 pp.298-307
DOI :
KACA와 AHAM 실내용 공기청정기 입자 청정화 능력 시험 방법간 비교 평가
김학준, 송동근, 홍원석, 한방우, 김용진*
한국기계연구원 그린환경기계연구본부
Comparison of the Methods of KACA and AHAM for Particle Cleaning Capacity Performance Test of an Indoor Air Cleaner
Yong‐jin Kim*
, Hak‐Joon Kim, Dong‐Keun Song, Won‐Seok Hong, Bang‐Woo Han
Environmental Systems Research Division, Korea Institute of Machinery & Materials(KIMM)
Abstract
Test methods of Korea Air Cleaning Association (KACA) and Association of Home ApplianceManufacturers (AHAM) for particle cleaning capacity performance of an indoor air cleaner were compared interms of the conditions of the test particle generation, the range of particle measurement and thecalculation methods for particle cleaning capacity, and types of the test particles. The performance test wasconducted in a 30 m3 chamber with the same test specimen and the test particles of each test weregenerated until the number concentration of 0.3 ㎛ particles reached 2.2 × 108 #/m3. The performance testresults showed that the cleaning capacity with the particles of higher surface area and volume density,regardless of the type of test particles, was higher than with those of lower and the capacity fromcalculation with 0.3~1 ㎛ particles was higher than with 0.3 ㎛ particles. Moreover, the cleaning capacitywith the calculation of KACA method was lower than with that of AHAM method in spite of using the sametest specimen.