Journal Search Engine
Download PDF Export Citation Korean Bibliography PMC Previewer
ISSN : 1738-4125(Print)
ISSN : 2287-7509(Online)
Journal of Odor and Indoor Environment Vol.6 No.2 pp.123-134
DOI :

박물관의 부유미생물 농도 분포 특성

이철민*, 김윤신, 김기연
한양대학교 환경 및 산업의학연구소

Distribution of Concentration for Airborne Microorgamisms in Museum

Cheol Min Lee*, Yoon Shin Kim, Ki Youn Kim
Institute of Environmental and Industrial Medicine, Hanyang University

Abstract

The aims of this study are to examine the concentration and identification of airborne organism at exhibithall and storage in museums and to provide fundamental data to protect cultural assests from damage. Thisstudy surveyed the concentration of airborne bacteria and fungi at exhibit hall and storage in museumslocated 4 metropolitans from July to October, 2007 and literature data on airborne microbes of museums inKorea that were publiced in relevant Korean journals. The concentrations of airborne bacteria and fungi werehigher than those in storage. Pseudomonas spp. and Bacillus spp for bacteria and Aspergillus spp. andPenicillium spp. for fungi were shown mainly in museums. Pooled average concentration of airborne bacteriain museums was 34.2±10.1 CFU/m3 for exhibit hall and 17.2±10.0 CFU/m3 for storage, respectively. Pooledaverage concentration of airborne fungi in museum was 26.0±11.2 CFU/m3 for exhibit hall and 16.6±11.0CFU/m3 for storage, respectively.

A9RCA18.pdf875.1KB

Reference