ISSN : 1738-4125(Print)
ISSN : 2287-7509(Online)
Journal of Odor and Indoor Environment Vol.7 No.1 pp.47-61
DOI :
학교 교실내 실내유해오염물질 분포 특성
전준민, 정만호, 이학성1), 강병욱2)*
순천제일대학 그린환경종합센터, 1)서원대학교 환경건설정보학과, 2)충주대학교 환경공학부
Characteristics of Indoor Hazardous Pollutants in Classroom of Schools
Byung-Wook Kang
2)*, Jun Min Jeon⋅Man Ho Jeong⋅Hak Sung Lee
1)
2)Division of Environmental Engineering, Chungju National University
Green Jeonnam Environmental Center, Suncheon First College
1)Department of Environmental, Civil and Information System, Seowon University
Abstract
The objective of this study was to estimate distribution of hazardous air pollutants and volatile organiccompounds at diverse indoor areas in school. The indoor air samples were collected at 19 school in threedifferent areas of southern Korea region from September to October 2009. The concentrations of PM-10and formaldehyde in all sampling sites were below indoor air quality guideline of the Ministry of Education,Science and Technology. The CO2 level and TBC (total bacteria count) were higher than the guideline for 4sites and 12 sites, respectively. The concentration of TVOC for 23 sites exceeded the guideline. Also, TVOClevel of metropolitan sampling sites were somewhat higher than small and medium-size city sampling sites.The concentration of indoor air pollutants affected by various conditions such as season, region, andindoor/outdoor environment. This study result shows that concentration of several pollutants such as CO2,TBC, and TVOC were higher than the guideline for some sampling sites. Therefore, it is necessary to manageindoor air quality and establish effective emission reduction strategies regard for characteristics of eachschool.
Reference