Journal Search Engine
Download PDF Export Citation Korean Bibliography PMC Previewer
ISSN : 1738-4125(Print)
ISSN : 2287-7509(Online)
Journal of Odor and Indoor Environment Vol.7 No.3 pp.135-146
DOI :

DNPH Cartridge를 이용한 대기 중 Formaldehyde 측정시험방법의 QA/QC 검토

홍원필, 임승민, 김기현*, 이은희1), 김윤신1)
세종대학교 환경에너지융합학과, 1)한양대학교 일반대학원 보건학과

QA/QC test of DNPH-Cartridge Sampling Method in the Analysis of formaldehyde

Ki Hyun Kim*, One Feel Hong, Sung Min Lim, Eun Hee Lee1), Yoon Shin Kim1)
Department of Environment & Energy, Sejong University
1)Department of Public Health Graduate school, Hanyang University

Abstract

In this study, the QA/QC test for the combined application of DNPH cartridge – HPLC/UV method wasinvestigated in the collection and analysis of formaldehyde in air using three types of DNPH cartridgesamplers made by three independent manufacturers. For these experiments, gaseous standards offormaldehyde (FA) were prepared at 7 concentration levels that fell in the range of 44.1~3400 nmol/mol.According to our analysis, the levels of cartridge blank (0.13 ~ 0.26 ng) are found to be fairly high to requireroutine check up for each experiment. The recovery patterns of FA were highly comparable betweendifferent cartridge products, when standard gases are supplied in the concentration range up to 177nmol/mol. All 3 types of DNPH cartridge exhibited highly similar recovery rates at concentrations below 1.7㎛ol/mol, while the maximum recovery was attained from the product B. The overall results of our studysuggest that one should calibrate the samples in the optimal range of recovery with routine check up ofblank values.

A9RCA30.pdf624.2KB

Reference