Abstract
This study aims to provide preliminary review for standardization of methods for evaluating reductionperformance of pollution-reducing building materials and to select commercially available pollution-reducingbuilding materials for assessing their current status. The ISO 16000-23 and -24 standards were used asreferences for standardizing the test methods. The sub test categories—stability of the supply airconcentration, type of the supply air, and supply air concentration—which were not included in the standardswere selected and conducted for the purpose of this study. Five (5) wall materials and 2 ceiling materialswere tested for formaldehyde reduction performance and 3 wall materials were tested for toluene reductionperformance. The study included experimental review of the essential test criteria such as stability of thesupply air, internal stability of the chamber, and recovery rate. The samples tested exhibited some reductionperformance for formaldehyde but little reduction performance for toluene.
Reference