오염물질 저감형 건축자재의 성능평가방법을 위한 기초연구

김현진, 김상철* ,정수경1)
한국건설생활환경시험연구원, 1)김포대학교 호텔조리과

A preliminary study on performance test methods for pollution-reducing building materials

Kim Sang Cheol*, Kim Hyun Jin, Soo-Kyung Jung1)
Korea Conformity Laboratories
1)Department of culimary Arts, Kimpo College

Abstract

This study aims to provide preliminary review for standardization of methods for evaluating reductionperformance of pollution-reducing building materials and to select commercially available pollution-reducingbuilding materials for assessing their current status. The ISO 16000-23 and -24 standards were used asreferences for standardizing the test methods. The sub test categories—stability of the supply airconcentration, type of the supply air, and supply air concentration—which were not included in the standardswere selected and conducted for the purpose of this study. Five (5) wall materials and 2 ceiling materialswere tested for formaldehyde reduction performance and 3 wall materials were tested for toluene reductionperformance. The study included experimental review of the essential test criteria such as stability of thesupply air, internal stability of the chamber, and recovery rate. The samples tested exhibited some reductionperformance for formaldehyde but little reduction performance for toluene.