ISSN : 2288-9167(Print)
ISSN : 2288-923X(Online)
Passive sampler를 이용한 하수처리시설에서 공정별 악취배출특성의 조사 연구
김한수, 이석준, 이용정, 김선태*
대전대학교 환경공학과
The survey on odor emission characteristics in a sewage treatment plant by using passive samplers
Sun-Tae Kim
*, Han-Soo Kim, Suk-Jun Lee, Yong-Jeong Lee
Department of Environmental Engineering, Daejeon University
(Received 28 December, 2013,Revised 14 March, 2014, Accepted 17 March, 2014)
Abstract
This research is carried out to investigate the odor emission characteristics in a sewage treatment plant. The plantwas divided into four areas (boundary areas, sewage treatment processes, sludge treatment processes and odortreatment plants), and measured around 27 sampling points. Odor characteristics from each areas were evaluatedby air dilution olfactory method and NH3/SO2/VOCs passive sampler, mainly in terms of spatial distribution. Themain odor emission sources were found out to be dewatering plant (S-4) of sludge, sludge transshipment place(S-5), and the outlet of odor treatment plant (B-2, B-3). The correlation between dilution number (OU) and ammoniaconcentration of passive sampler appeared to be low; correlation coefficient 0.49, but correlation coefficient for theresults of sulfur dioxide and toluene were very high, 0.95 and 0.93, respectively. These results indicate that odorcompounds form sewage treatment facility are mainly due to sulfur compounds and volatile organic compounds.
Reference