Journal Search Engine
Download PDF Export Citation Korean Bibliography PMC Previewer
ISSN : 2288-9167(Print)
ISSN : 2288-923X(Online)
Journal of Odor and Indoor Environment Vol.15 No.2 pp.154-163
DOI : http://dx.doi.org/10.15250/joie.2016.15.2.154

Study on the estimation of configuration ratio of ion compound with carbonate in subway

Yongil Lee,Kyoung Bin Lee,Jin Sik Kim,Duckshin Park,Shin Do Kim

Abstract

The following study aims to estimate the configuration ratio of the ion compounds that identifies the cause of fine dust and ways to reduce it. In this study, the physical and chemical properties of fine particles in a tunnel and the configuration form of ionic composition were interpreted to establish reasonable measurement for air quality management. Seasonal measurements were performed by collecting samples from the Mia sageori subway station. Chemical Mass Balance (CMB) model was used to estimate the configuration ratio of ions in this study. The results showed that the test performed outside showed about 56.4% of total ion, with (NH4)2SO4, NH4NO3, CaCO3 and NaCl showing concentrations of 2.138 μg/m3, 1.957 μg/m3, 1.697 μg/m3 and 1.600 μg/m3, respectively, while the results indoor had CaCO3, NH4NO3, (NH4)2SO4 and NaCl showing concentrations of 2.272 μg/m3, 2.204 μg/m3, 1.656 μg/m3 and 1.342 μg/m3, respectively, about 65.1% of total ion. During the usage of tunnel, it was found that CaCO3, NH4NO3, (NH4)2SO4 and MgCO3 showed concentrations of 3.464 μg/m3, 1.732 μg/m3, 1.698 μg/m3 and 0.582 μg/m3, respectively, total ion of 70.2% was presented.

초록

Figure

Table