Mass Balance 모델을 이용한 신축공동주택의 휘발성유기화합물 발생량 추정

심상효1)*, 김윤신1), 김화선2), 이철민3), 이송권4), 노영만3)
1)한양대학교병원 산업의학과, 2)안산1대학, 3)한양대학교 환경 및 산업의학연구소
4)대구 한의대학교 보건학부

Emssion Rate Estimation for the Volatile Organic Compounds(VOCs) in Newly Constructed Apartments Using a Mass Balance Model

Sang hyo Sim1)*, Yoon Shin Kim1), Hwa-Sun Kim1), Cheol Min Lee2), Young-Man Roh2), Song kwon Lee3)
1)Ansan college radiological technology
Department of Occupational and Environmental Medicine, Hanyang University Medical Cente
2)Institute of Environmental and Industrial Medicine Hanyang University
3)Faculty of Health Science, Daegu Haany University
Received 31 July 2006, accepted 25 September 2006

Abstract

This study was performed to estimate the emission rate of volatile organic compounds (VOCs) and toevaluate the risk level affected by indoor air pollutants (IAPs) in 27 new apartments (prior to residence) inSeoul City from December 2004 to March 2005.The indoor air pollutants investigated in this study include formaldehyde, several aromatic VOCs (benzene,toluene, styrene, xylene, and ethylbenzene). All measurements were made based on the standard method ofMinistry of Environment in Korea. The indoor concentration levels for benzene, xylene, toluene, ethylbenzene,styrene, and formaldehyde have significant increase trend 5 hours after closing windows and doors. Levels ofair pollutants did not exhibit significant difference between living rooms and bedrooms. The air exchangerates by the concentration decay method using SF6 were 0.37 for low floor, 0.32 for middle floor, and 0.75for high floor. The emission rate showed the highest level in the middle floor and second one in the lowfloor, when estimated by the IAQ model for benzene, toluene, ethylbenzene, xylene, styrene, andformaldehyde. Considering the above result, it is suggested that the estimation of emission rate beconsidered when the new apartment is designed and constructed with respect to construction materials toemit low VOCs. Moreover, the related regulation should be established for IAQ management.