Journal Search Engine
Download PDF Export Citation Korean Bibliography PMC Previewer
ISSN : 1738-4125(Print)
ISSN : 2287-7509(Online)
Journal of Odor and Indoor Environment Vol.5 No.1 pp.1-11
DOI :

대전지역 지하주차장의 휘발성유기화합물(VOCs) 농도분포 연구

하덕호, 편무권, 이봉우, 김종헌, 김선태1)*
대전보건환경연구원, 1)대전대학교 환경공학과

A Study on the Concentration Levels of VOCs at the Underground Parking Lots in Daejeon

Sun-Tae Kim1)*, Duk-Ho Ha, Moo-Kwon Pyun, Bong-Woo Lee, Jong-Heon Kim
1)Dept. of Environmental Engineering, Daejeon University
Daejeon Health and Environment Research Institute

Abstract

In this study, VOCs originating from vehicles were measured at 8 underground parking lots(two apartments,four department stores, and two large-scale marts) in Daejeon. The indoor air quality at underground parkinglots of the department stores and marts was affected by the availability of the ventilation facility and theiroperation frequency. At the underground parking lots with a ventilation facility, the maximum VOCsconcentration was 727㎍/㎥, and the minimum was 73.5㎍/㎥. The average concentration ratio of BTEX toTVOCs at the underground parking lots was almost constant, which was approximately 44.8%. TVOCs andBTEX were strongly correlated with a correlation coefficient (r) of 0.88. The relative ratio of benzene,toluene, ethylbenzene and xylene was 1 : 9.51 : 0.71 : 2.53, directly reflecting the influence of vehiclessources.

A9R9837.pdf454.2KB

Reference