소형챔버를 이용한 건축자재의 휘발성유기화합물과 폼알데하이드 방출량 평가

강윤경*, 김현진1), 이윤규
한국건설기술연구원 건축도시환경연구실, 1)한국건자재시험연구원 안전환경평가센터

A Study on VOCs and HCHO Emission of Building Materials Using the 20L Test Chamber

Yoon-Kyung Kang*, Hyun-Jin Kim1), Yun-Gyu Lee
Building and Urban environment laboratory, Korea Institute of Construction Technology
1)The center of Safety and Environment, Korea Institute of Construction Materials

Abstract

This study was performed to analysis the concentration of TVOC, 5VOC and formaldehyde for buildingmaterial of total 262 using 20L test chamber. The concentration of TVOC, 5VOC and formaldehyde weremeasured 1.001㎎/㎡・h, 43.032㎍/㎡・h, 0.012㎎/㎡・h, respectively. TVOC concentration of paint and floorcovering occupied the largest concentration of the indoor building materials as 2.689㎎/㎡・h, 2.120㎎/㎡・h,respectively. 5VOC concentration of floor covering was measured 106.636㎍/㎡・h. Toulene and xylene wereoccupied the largest part of the 5VOC as 51.2% and 33.1%, respectively. The concentration of formaldehydefor furniture materials occupied the largest concentration of the indoor building material as 0.072㎎/㎡h.

A9RDDDE.pdf887.9KB