Journal of Odor and Indoor Environment Vol.1 No.2 pp.144-155
DOI :

다중이용시설에서의 실내공기질 조사

김윤신, 노영만*, 홍승철, 이철민, 전형진, 김종철, 조정현
한양대학교 환경 및 산업의학연구소

A Survey of Indoor Air Quality in Public Facilities

Young Man Roh*, Yoon Shin Kim, Seung-Cheol Hong, Choel Min Lee, Hyung Jin Jun, Jong Choel Kim, Jung Hyun Cho
Institute of Environmental and Industrial Medicine, Hanyang University
Received 24 August 2004, accepted 7 January 2005

Abstract

This study was performed to investigate the characteristics of indoor air quality (IAQ) in 30 publicfacilities from February to April, 2004 in Seoul. The collected samples are PM10, formaldehyde, and totalsuspended bacteria in indoor air and measured by the IAQ standard method of Ministry of Environment inKorea(M.E.K). As the results of the survey, the mean concentration of PM10 was 55.19 ㎍/m3 in indoor air and51.15 ㎍/m3 in outdoor air. The mean concentration of PM10 in the Kindergarten was higher than the IAQstandards by established by M.E.K. The mean concentration of formaldehyde was 43.08 ㎍/m3 in indoor airand 5.05 ㎍/m3 in outdoor air, respectively. All of them were less than IAQ standards of Korea. Theconcentration of total suspended bacteria in the streamer room was higher than IAQ standards. Theconcentration of formaldehyde was different according to the year of construction of building. Totalsuspended bacteria in streamer room was necessary for control. Moreover, this study was for investigationa part of indoor air pollution condition in public facilities. It means that this study can't represent for all ofpublic facilities. Therefore, we suggest that long and middle term country plan for management of IAQshould be established through long-term and continuous investigation of IAQ condition.

A9RD847.pdf383.1KB

Reference